DeltaV Safety Instrumented System (SIS)™ with IS Electronic Marshalling


  • Intrinsically Safe I/O anywhere you need it
  • Integrated galvanic isolation per channel
  • Optimized process reliability
  • Simplified safety lifecycle management
  • Flexibility to meet project needs
  • Reduces installed cost of system
  • Field mounted capable hardware

DeltaV Safety Instrumented System (SIS)™
Introduction


        The DeltaV SIS™ process safety system has a uniquely scalable modular architecture that is based on the CHARMs Smart Logic Solver (CSLS) and the unprecedented flexibility and ease of use of the Emerson Electronic Marshalling solution. Each CSLS provides I/O processing, SIL 3-capable logic solving, and diagnostics in a single logic solver. The CSLS supports up to 96 individually configurable channels, allowing flexibility for implementing safety instrumented functions and is designed specifically for multi-core home run cables or field junction box installation. All communications are completely redundant from the channel (LS IS CHARM) to the CSLS. Integrated HART® I/O brings field diagnostics into the CSLS.

        The addition of Intrinsically Safe (IS) LS CHARMs provides significant savings in system design, installation cost, and ease of maintenance expected with Electronic Marshalling, with the added safety for field wiring to hazardous areas. The reduced footprint and associated elimination of separate barriers and the associated inter cabinet wiring makes for a more robust installation with significant cost savings.


DeltaV Safety Instrumented System (SIS)™ Ordering Information


  • SZ Controllers and CSLSs

*Redundant SZ Controller Assembly (vertical carrier)  -SS3001

*Redundant SZ Controller Assembly (horizontal carrier)  -SS3003

*Redundant SZ Controller Assembly (keylock - vertical carrier)  -SS3002

*Redundant SZ Controller Assembly (keylock - horizontal carrier)  -SS3004

*Redundant CSLS Assembly - Copper  -SS6501T01

*Redundant CSLS Carrier Assembly - Copper  -SS6501T05

*Redundant CSLS  -SS6502

  • CSLS IS CHARM Baseplates

*CSLS IS CHARMS Baseplate Assembly with Standard IS CHARM Terminal Blocks  -SS4608T01

  • CSLS Baseplate Address Plugs

*CSLS IS CHARMS Baseplate Assembly with Standard IS CHARM Terminal Blocks  -SS4608T01

  • CSLS Baseplate Address Plugs

*Addressing Plugs  -SS4602

*Addressing Plugs  -SS4613

  • CSLS Baseplate Extenders, Terminators, & Cables

*CSLS Baseplate Terminator, Top (Male)  -SS4604T03

*CSLS Baseplate Terminator, Bottom (Female)  -SS4604T04

*CSLS Baseplate Extender with Cable Connectors, Top (Male)  -SS4603T05

*CSLS Baseplate Extender with Cable Connectors, Bottom (Female)  -SS4603T06

*CSLS Baseplate Cables  -SS4605T02

*CSLS Baseplate Cables  -SS4605T03

*CSLS Baseplate Cables  -SS4605T04

  • CSLS Baseplate Labeling

*CSLS Baseplate Identifiers  -SS4606T03

*CSLS Baseplate Channel Identifier Labels  -SS4606T02

  • LS IS CHARMs

*LS IS DI NAMUR  -SS4305T01

*LS IS AI 4-20 mA HART  -SS4307T01

*LS IS Thermocouple/mV  -SS4309T01

*LS IS RTD  -SS4310T01

  • IS CHARMs and IS Terminal Block Assemblys

*LS IS Thermocouple/mV CHARM with IS Thermocouple/mV Terminal Block  -SS4309T51

  • IS CHARM Protection Cover

*IS CHARM Protection Cover  -SS6104

  • SZ and CSLS Spare Part Ordering Information

*Power Terminal Plug for CSLS, and Dual Vertical and Horizontal Safety Carriers -KJ4005X1-BF1

*Ethernet Isolation Port; twisted copper; for Dual Vertical or Horizontal Safety Carriers -KL1604X1-BA1

*Keylock Ethernet Isolation Port; twisted copper; for Dual Vertical or Horizontal Safety Carriers -KL1604X1-BB1

*Power Module for CSLS Carriers -KL1501X1-BA1

*Set of 2 Replacement Keys for Keylock Switch on CSLS and Dual Vertical and Horizontal Safety Carriers -SS6201

  • LS IS CHARM Labeling Part Ordering Information

*Channel Identifier Labels for CSLS IS CHARM Baseplates; Package of eight -SS4609T01

*CSLS IS Charm Baseplate Separation Wall; Package of nine -SS4609T02

*Replacement Fuse for SE4610T01 Fuseholder Assembly -KL4510X1-FA1

*Replacement Fuseholder for SE4610T01 Fuseholder Assembly -KL4510X1-GA1